Step 1: Define the Hazard

This is the first step, you want to know what you are dealing with, you need to identify exactly what you are trying to detect, some of the most common hazards are the following.

  • Flammable gases (methane, propane, hydrogen, solvents)
  • Toxic gases (H₂S, CO, NH₃, Cl₂, silane, arsine)
  • Oxygen deficiency or enrichment
  • Volatile Organic Compounds (VOCs)

These are the questions you need to ask 

        What gas could be released?

  • What concentration is dangerous?
  • Is the primary concern toxicity, explosion risk, or oxygen displacement?

A detector must be selected for the specific target gas. No single technology can detect every gas effectively.

Step 2: Understand the Application

Knowing the specific gas they you want to detect is not enough, you need to determine where the detector will be installed. 

Here are some of the examples.

ApplicationTypical Hazard
RefineryHydrocarbon leaks
Chemical plantToxic gas releases
Semiconductor facilitySpecialty toxic gases
Wastewater treatmentH₂S, CH₄
Boiler roomCO, natural gas
Refrigeration plantNH₃
Battery roomH₂ accumulation

The environment often dictates the detector technology and housing requirements. Honeywell industrial references highlight different detector solutions for oil & gas, chemical processing, wastewater, cold storage, and semiconductor applications.

Step 3: Select the Proper Sensor Technology

Selecting the right sensor technology is crucial for the gas detection system to work as it was designed, depending of the type of gas and environment you can select the right sensor for the application, here are some of the technologies recommended depending on what is the target gas.

Electrochemical Sensors

Best for:

  • CO
  • H₂S
  • NH₃
  • O₂
  • Cl₂

Advantages:

  • High sensitivity
  • Excellent ppm-level measurement

Limitations:

  • Limited sensor lifespan
  • Potential cross-sensitivity

Catalytic Bead Sensors

Best for:

  • Combustible gases
  • General LEL detection

Advantages:

  • Broad combustible gas response
  • Cost effective

Limitations:

  • Can be poisoned by contaminants
  • Requires oxygen to function

Infrared (IR) Sensors

Best for:

  • Hydrocarbon gases
  • CO₂

Advantages:

  • Resistant to poisoning
  • Low maintenance
  • Fast response

Honeywell’s Searchpoint Optima Plus IR detector is designed for harsh industrial environments where catalytic poisons may be present. 

PID Sensors

Best for:

  • VOCs
  • Solvents

Advantages:

  • Highly sensitive
  • Fast response

Limitations:

  • Requires regular calibration

Ultrasonic Gas Leak Detectors

Best for:

  • Pressurized gas releases
  • Outdoor windy environments

Advantages:

  • Detects leaks before a gas cloud reaches a sensor

Step 4: Determine Detection Range

I have seen customers who select a 0 to 250 ppm co detector in an application that the co leaks can reach to 500 ppm and the detector is in constant overrange and it is alarming all the time.

You need to figure out the range of the leaks expected in your application and select the sensor range acordingly.

Select an appropriate measurement range.

Examples:

Gas TypeTypical Range
H₂S0–100 ppm
CO0–500 ppm
Oxygen0–25% vol
Methane0–100% LEL

The range must match both:

  • Expected operating concentrations
  • Safety limits

Step 5: Evaluate Environmental Conditions

You need to select your detector depending on the environment, for example if you want to detect Methane in normal environment you need a maybe the catalytic bead sensor is the best option but if you want to detect the same gas (methane) in the environment where the O2 levels are less than 10%, the infrared sensor is the best option.

Here are conditions you need to consider.

Temperature

  • Extreme heat or cold

Humidity

  • Condensation risk
  • Corrosive environments

Dust and Water

  • IP66/IP67 requirements

Vibration

  • Compressors
  • Rotating equipment

Corrosive Atmospheres

  • Offshore platforms
  • Chemical plants

Detector materials should be selected accordingly, often using stainless steel in harsh environments. 

Step 6: Choose Point Detection or Open-Path Detection

In fixed gas detection you can select to detect the gas at a specific point or on a certain path.

Point Detectors

Used when:

  • Leak source is known
  • Monitoring pumps, valves, flanges, compressors

Pros:

  • Highly localized measurement
  • Lower cost

Open-Path Detectors

Used when:

  • Large areas need coverage
  • Perimeters or fence lines require monitoring

Pros:

  • Covers long distances
  • Detects moving gas clouds

Many facilities use a combination of both technologies. 

Step 7: Determine Detector Placement

The location of the sensor is critical, you need to study the guy you are detection and check it is relative density ( you can find this on the msds).

For Light Gases

Install high.

Examples

  • Hydrogen
  • Methane

For Heavy Gases

Install low.

Examples:

  • Propane
  • Butane
  • H₂S

Also you need to consider the following.

  • Leak sources
  • Airflow patterns
  • Ventilation systems
  • Obstructions

A poorly placed detector can miss a leak even if the detector itself is correct.

Step 8: Verify Required Certifications

Certifications are important, they are both required by local authorities and insurance companies.

Depending on the location of your project, check with local authorities and figure out which certifications are needed.

Typical certifications include

  • ATEX
  • IECEx
  • UL
  • CSA
  • FM

Industrial installations often require detectors certified for hazardous locations. Honeywell fixed gas detection products include multiple global certifications for hazardous-area applications. 

Step 9: Consider System Integration

Fixed detector usually are connected to a larger control or building management system, you need to select the detector that can easily integrate with the current or future system.

Determine how the detector will communicate with the control system.

Common outputs

  • 4-20 mA
  • HART
  • Modbus
  • Relay outputs

Also verify compatibility with:

  • DCS
  • PLC
  • Gas controllers
  • Safety systems

Many modern transmitters support multiple communication methods and hot-swappable sensors to simplify maintenance.

Step 10: Evaluate Maintenance Requirements

Before you commit to buy the detector, you need to contact the manufacturer or the distributor and check what is the maintenance requirements like calibrations, you need to understand the frequency and the procedure, you need to figure out if your technicians will need new training or they can do it with minimum training.

These are some questions you can ask yourself.

  • How often must calibration be performed?
  • What is the expected sensor life?
  • Are replacement sensors available?
  • Can calibration be performed remotely?

Consider total lifecycle cost, not just purchase price.

Step 11: Perform a Risk-Based Coverage Assessment

This step with help you to figure out how many detectors you need, and to make sure that the area is protected properly.

Create a detector mapping study

  1. Identify credible leak sources.
  2. Determine gas release scenarios.
  3. Model dispersion patterns.
  4. Confirm detector coverage.
  5. Validate alarm actions.

A detector that is technically correct but poorly located provides little protection.

Quick Selection Matrix

If You Need to DetectRecommended Technology
H₂SElectrochemical
COElectrochemical
OxygenElectrochemical
MethaneIR or Catalytic
HydrocarbonsIR or Catalytic
CO₂IR
VOCsPID
High-pressure gas leaks outdoorsUltrasonic

Final Rule of Thumb

When selecting a fixed gas detector, always answer these five questions first:

  1. What gas am I detecting?
  2. What concentration must be detected?
  3. Where will the detector be installed?
  4. What environmental conditions exist?
  5. What action should occur when gas is detected?

If these five questions are answered correctly, the proper detector technology, location, and system architecture usually become clear.